IMPACT




Two lengths of randomly selected hubless cast iron soil pipe were joined with an MG COUPLING, torqued to 175 inch-pounds, and was impacted in the center using an IAPMO Impact Tester with a ½" ball.
   
MG COUPLING (sizes tested) Maximum Impact (foot-pounds) Results
2" 22 No Breakage
3" 23 No Breakage
4" 29 No Breakage
5" 42 No Breakage
6" 59 No Breakage
8" 64 No Breakage