<< Go Back

>>>>
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10

 

DEFLECTION (ASTM A-1056)

Two lengths of randomly selected hubless cast iron soil pipe were joined with an MG COUPLING, torqued to 175 inch-pounds, and the ends of the assembly were sealed with test plugs. One pipe was rigidly supported while the other was unrestrained. The assemble was filled with water and the hydrostatic pressure was held at 4.3 psi for the duration of the test. The end of the unrestrained pipe was raised ½" per lineal foot of pipe length and maintained for 5 minutes at 4.3 psi.  
MG COUPLING - Sizes Tested Results
1½", 1½"x 2", 2", 3", 4", 5", 6", 8", 10" No Leakage Occurred