The chart below shows the results of the Harco tests. Below the chart is a graphic illustration of the same test data.
 
# Structure Native
Potential
(mv)
Connected Potential
7/26 8/02 8/16 8/23 9/28
I(Output)
(ma)
Bin#
1. S/S Bolt to 4"
P.C.C.*
-260 -750 -760 -740 -750 -790 .82 1
2. S/S Bolt to 4"
B.C.**
-260 -800 -810 -810 -780 -760 .60 1
3. S/S Bolt to 2"
P.C.C.*
-300 -750 -720 -750 -750 -790 .82 1
4. S/S Bolt to 2"
B.C.**
-290 -750 -760 -780 -780 -760 .70 1
5. S/S Bolt to 4"
P.C.C.*
-270 -740 -750 -740 -730 -810 .49 2
6. S/S Bolt to 4"
B.C.**
-270 -780 -800 -780 -780 -760 .55 2
7. S/S Bolt to 2"
P.C.C.*
-260 -760 -760 -770 -750 -800 .46 2
8. S/S Bolt to 4"
B.C.**
-300 -740 -790 -800 -800 -765 .49 2
*Pitch coated coupling halves Bin #1 - Synthetic Seawater (23 Ohm-cm)
**Bare coupling no coating Bin #2 - Fresh Water (1500 Ohm-cm)